XPSBAC14AP

SKU

$78.57

Short Description

safety module, Harmony XPS, estop or guard, connected to supply terminals 24V AC or DC , no inputs, screw

For more information click here

For more information click here

describe

Range of product Harmony Safety Automation
Product or component type Safety module
Safety module name XPSBAC
Safety module application For emergency stop and protective guard applications
Function of module Emergency stop button with 2 NC contacts
Guard monitoring with 1 or 2 limit switches
Safety level Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1
Can reach SILCL 3 for normally open relay contact conforming to IEC 62061
Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1
Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061
Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Safety reliability data MTTFd > 30 years conforming to ISO 13849-1 for normally open relay contact
Dcavg >= 99 % conforming to ISO 13849-1 for normally open relay contact
PFHd = 0.95E-09 conforming to ISO 13849-1 for normally open relay contact
HFT = 1 conforming to IEC 62061 for normally open relay contact
PFHd = 0.95E-09 conforming to IEC 62061 for normally open relay contact
SFF > 99% conforming to IEC 62061 for normally open relay contact
HFT = 1 conforming to IEC 61508-1 for normally open relay contact
PFHd = 0.95E-09 conforming to IEC 61508-1 for normally open relay contact
SFF > 99% conforming to IEC 61508-1 for normally open relay contact
Type = B conforming to IEC 61508-1 for normally open relay contact
MTTFd > 30 years conforming to ISO 13849-1 for normally closed relay contact
DC > 60 % conforming to ISO 13849-1 for normally closed relay contact
PFHd = 0.95E-09 conforming to ISO 13849-1 for normally closed relay contact
HFT=0 conforming to IEC 62061 for normally closed relay contact
PFHd = 0.95E-09 conforming to IEC 62061 for normally closed relay contact
SFF > 60% conforming to IEC 62061 for normally closed relay contact
HFT=0 conforming to IEC 61508-1 for normally closed relay contact
PFHd = 0.95E-09 conforming to IEC 61508-1 for normally closed relay contact
SFF > 60% conforming to IEC 61508-1 for normally closed relay contact
Type = B conforming to IEC 61508-1 for normally closed relay contact
Electrical circuit type NC pair
Connections – terminals Removable screw terminal block, 0.2…2.5 mm² solid or flexible
Removable screw terminal block, 0.25…2.5 mm² flexible with ferrule single conductor
Removable screw terminal block, 0.2…1.5 mm² solid or flexible twin conductor
Removable screw terminal block, 2 x 0.25…1 mm² flexible with ferrule without cable end, with bezel
Removable screw terminal block, 2 x 0.5…1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage 24 V AC – 15…10 %
24 V DC – 20…20 %